AC & DC Voltage Transducer

At ELDAC Process Automation, our Power Transducers offer precise measurement and conversion of electrical power into industry-standard signals, enabling industries to monitor and control their energy usage with accuracy. These transducers provide crucial data on power consumption, which is essential for optimizing energy efficiency, improving load balancing, and ensuring the overall reliability of power systems. Our power transducers are designed for seamless integration with various monitoring and control systems, allowing industries to track power usage in real-time, identify inefficiencies, and take corrective action as needed. Built for industrial-scale operations, they offer high reliability and durability, ensuring continuous performance in demanding environments. Whether used in power generation, energy distribution, or industrial automation, ELDAC’s power transducers provide industries with the insight they need to enhance operational efficiency and reduce energy waste.

LTPE – AC Voltage Transducer

Converts alternating voltage from a voltage transformer into a standard process signal

  • Minimum ripple
  • Isolation up to 2000 V AC
  • High-density mounting
  • Conforms to IEC 60688
Input ( factory Set ):
  • 0 – 8 V AC (CE not available), 0 – 12 V AC (CE not available)
  •  0 – 110 V AC, 0 – 220 V AC, 0 – 90 V AC ,0 – 150 V AC, 0 – 300 V AC, 0 – 550 V AC
Output Factory set:
  • 4 – 20 mA DC , 0 – 20 mA DC,   0 – 10 mA DC  0 – 5 mA DC
  •  0 – 10 mV DC  , 0 – 100 mV DC ,  0 – 1 V DC ,0 – 10 V DC  0 – 5 V DC , 1 – 5 V DC
Power Supply :
  • 110 VAC, 230 VAC, 24 VAC

VTR Series – AC Voltage Transducer

Voltage transducers are high-performance transducers for sensing voltage in installations. They are available in an AC or DC Series and come in a variety of nominal voltages.

Features:
  • AC or DC models
  • Standard 4–20 mA powered output
  • Industry standard output makes use with existing controllers, data loggers and SCADA equipment easy and reliable
  • Input/Output Isolation: Input and output circuitry electrically isolated for improved
  • safety of use
  • Compact DIN rail mount case Transducer housing mounts to standard DIN rail or to a flat panel
  • AC Input, True RMS, 120 to 600 V
Input:   

50-150 V: 73 KΩ, 240-300 V: 46 KΩ, 400-500 V: 300 KΩ, 600 VAC: 365 KΩ

Output:   

4–20 mA proportional

DC Voltage Transduce

VTD Series

Input:   

15 V: 25 KΩ, 25 V: 42 KΩ, 50 V: 82 KΩ, 150 V: 250 KΩ, 300 V: 500 KΩ, 600 V: 1.00 MΩ

Output:   

4–20 mA (capped at 24 mA max.); 0–5 VDC (capped at 5.75 VDC); 0–10 VDC (capped at 11.5 VDC)

Features:

DC Input, 15 to 600 V

VTD-BD Series

Input:   

15 V, 25 V, 50 V, 150 V, 300 V, 600 VDC

Output:   

+/-5 VDC +/-10 VDC

Features:

DC Input, 15 to 600 V

Features:
  • Converts a DC input into an isolated DC signal
  • High-density mounting
  • Power LED
Input (factory Set ): 
  • Current: 4 – 20 mA DC, 2 – 10 mA DC, 1 – 5 mA DC, 0 – 20 mA DC, 0 – 16 mA DC, 0 – 10 mA DC, 0 – 1 mA DC, 10 – 50 mA DC
  • Voltage: 0 – 1 V DC, 0 – 5 V DC, -10 – +10 V DC, -5 – +5 V DC
Output (factory Set ): 
  • Current: 4 – 20 mA DC, 0 – 20 mA DC
  • Voltage: 0 – 10 mV DC, 0 – 100 mV DC, 0 – 1 V DC, 0 – 10 V DC, 0 – 5 V DC, -10 – +10 mV DC, -100 – +100 mV DC, -1 – +1 V DC,  -10 – +10 V DC, -5 – +5 V DC
Power Supply :
  • AC Power: 85 – 264 V AC
  • DC Power: 24 V DC
Features:
  • Converts DC input from a sensor into a standard process signal
  • Fast response type available
  • Typical Applications
  • Isolation between control room and field instrumentation
Input:   
  • Current: 4 – 20 mA DC, 2 – 10 mA DC, 1 – 5 mA DC, 0 – 20 mA DC, 0 – 1 mA DC, 10 – 50 mA DC, 0 – 10 μA DC, 0 – 100 μA DC, -1 – +1 mA DC, : -10 – +10 mA DC
  • Voltage: 0 – 10 mV DC, 0 – 50 mV DC, 0 – 60 mV DC, 0 – 100 mV DC, 0 – 1 V DC, 0 – 10 V DC, 0 – 5 V DC, 1 – 5 V DC, -10 – +10 V DC, -5 – +5 V DC
Output:   
  • Current: 4 – 20 mA DC, 2 – 10 mA DC, 1 – 5 mA DC, 0 – 20 mA DC, 0 – 16 mA DC ,0 – 10 mA DC, 0-1 mA DC
  • Voltage: 0 – 10 mV DC, 0 – 100 mV DC, 0 – 1 V DC, 0 – 10 V DC, 0 – 5 V DC, 1 – 5 V DC, -10 – +10 V DC, -5 – +5 V DC
Power Supply :
  • AC Power: 24 V AC, 85 – 264 V AC, 100 – 240 V AC
  • DC Power: 24 V DC, 11 – 27 V DC, 110 V DC

M2VF3

Features:
  • Converts DC input from a sensor into a standard process signal
  • Frequency characteristics 12 kHz (-3 dB) • 30-microsecond response
  • Typical Applications
  • Isolation for a vibration analysing system
  • Isolation for Discharge/Charge teste
Input:
  • Voltage: -100 – +100 mV DC ,10 – +10 V DC ,-5 – +5 V DC ,-20 – +20 V DC , -20 – +20 mV DC, -24 – +24 mV DC,-40 – +40 mV DC, -85 – +85 mV DC, -164 – +164 mV DC, -200 – +200 mV DC, -15 – +15 V DC, -25 – +25 V DC, 55 – +55 V DC, -60 – +60 V DC, -300 – +300 V DC, -350 – +350 V DC,  -400 – +400 V DC , -600 – +600 V DC, -800 – +800 V DC
Output:
  • Voltage: -10 – +10 V DC (Load resistance 2000 Ω min.)
Power Supply :
  • DC Power: 24 V DC

Universal Voltage Transducer

VTU-OS Series

Input:   

0–800, 1000 or 1200 VAC or VDC

Output:   

4–20 mA, 0–5 VDC, 0–10 VDC

VTU-DIN Series

Input:   

15, 25, 50, 60: >220 KΩ, 120: >410 KΩ, 150, 240, 300, 400, 500, 600 VAC/VDC: 620 KΩ

Output:   

4–20 mA proportional (capped at 31 mA max.); 0–5 VDC (capped at 7.75 VDC); 0–10 VDC (capped at 11.5 VDC)

Let Us Know Your Needs

Get in touch with our specialists to explore the best automation solutions for your industry.



    Scroll to Top